Medline medical procedure convenience kits labeled as: 1) MIDDLE EAR CDS, Kit SKU CDS984347O; 2) HEAD AND NECK CDS-LF, Kit SKU CDS984857N; 3) NECK PACK-LF, Kit SKU DYNJ0966130K; 4) NECKLINE PACK-LF, Kit SKU DYNJ51440B; 5) THYROID PACK, Kit SKU DYNJ58742J; 6) ENT I, Kit SKU DYNJ63781B; 7) NECK PACK, Kit SKU DYNJ82751B; 8) NOSE PACK, Kit SKU DYNJ82753C; 9) WMC COCHLEAR IMPLANT ADD ON, Kit SKU DYNJ907206G. — Reason: Medline kits were manufactured and distributed containing MASTISOL liquid adhesive which was recalled due to complaints that the butyrate tubing cracked during actuation of the vials of MASTISOL Liquid Adhesive. — Status: Ongoing
Conductivity Standard Solution Catalog/Model Numbers: 10001, 10011, 10021, 10032, 10040, 10040c, and 10041 Conductivity Standard Solutions are a secondary standard solution used for the calibration of conductivity cells together with conductivity meters — Reason: due to a defect associated with the conductivity values of the solution used to calibrate meters and result in the reporting of incorrect conductivity values for dialysate. — Status: Ongoing
Medline medical procedure convenience kits labeled as: CIRCUMCISION PACK, Kit SKU DYNJ16826O — Reason: Medline kits were manufactured and distributed containing MASTISOL liquid adhesive which was recalled due to complaints that the butyrate tubing cracked during actuation of the vials of MASTISOL Liquid Adhesive. — Status: Ongoing
Codman CereLink ICP Sensor Basic Kit. Catalog Number: 826850. The Codman CereLink ICP Sensor Basic Kit consists of the CereLink ICP Sensor (ICP Sensor) and a 14-gauge Tuohy needle with stylet. The ICP Sensor is a nylon tube with a microminiature strain gauge pressure transducer (sensing element) mounted at one end and an electrical connector at the other end. It is designed for use with a Codman intracranial pressure monitoring device. The ICP Sensor Basic Kit is designed for use with the Codman Cranial Hand Drill. The drill facilitates access to the intraparenchymal area. The drill is also available as a component of the Codman Cranial Access Kit. Use of the ICP Sensor Basic Kit is indicated when direct ICP monitoring is required. The kit is indicated for use in both subdural and intraparenchymal pressure monitoring applications only. — Reason: Potential corrosion stains on the surface of the 14-gauge Tuohy Needle that is included in the Microsensor and Cerelink ICP Kits. — Status: Ongoing
Brand Name: Elekta Medical Linear Accelerator Product Name: Elekta Synergy, Elekta Harmony, Elekta Infinity, Versa HD Software Version: N/A Product Description: Digital Linear Accelerator Component: No — Reason: Due to a manufacturing issue and electrical grounding of systems. — Status: Ongoing
Estrone RIA, REF: DSL8700 — Reason: The affected Estrone RIA kit lots may rarely give falsely high patient results which might cause Temporary injury of Remote probability. Only in some (very rare) cases may the issue occur. — Status: Ongoing
da Vinci SP, SP Access Port Kit, Large Incision Reference Numbers:430073 (2.7-4cm,SP1098, Box) & 430075 (2.7-7cm,SP1098,Box) — Reason: Access Port System tray may develop cracks potentially resulting in a sterility breach. — Status: Ongoing
Allura Xper FD10F; Model Number: 722002; — Reason: Philips has identified that in a limited number of impacted systems the drip tray beneath the cooling unit was not installed under previous field corrections, or evidence of the implementation was not adequately documented. If it is not installed, there is a potential for coolant liquid to contact electrical components. This could lead to electrical short-circuits, which may trigger system fuses and result in system shutdown. — Status: Ongoing
Brand Name: Broselow Product Name: Broselow Pediatric Emergency Rainbow Tape Model/Catalog Number: 7700RE Software Version: Not Applicable Product Description: The Broselow Tape is a length- and weight-based reference tool specifically designed for pediatric emergency care. Component: No — Reason: Product contains potentially harmful dosing errors for Vecuronium, Flumazenil, and Ketamine. — Status: Ongoing
Allura Xper FD10/10; Model Number: 722027; — Reason: Philips has identified that in a limited number of impacted systems the drip tray beneath the cooling unit was not installed under previous field corrections, or evidence of the implementation was not adequately documented. If it is not installed, there is a potential for coolant liquid to contact electrical components. This could lead to electrical short-circuits, which may trigger system fuses and result in system shutdown. — Status: Ongoing
Allura Xper FD20; Model Number: 722028; — Reason: Philips has identified that in a limited number of impacted systems the drip tray beneath the cooling unit was not installed under previous field corrections, or evidence of the implementation was not adequately documented. If it is not installed, there is a potential for coolant liquid to contact electrical components. This could lead to electrical short-circuits, which may trigger system fuses and result in system shutdown. — Status: Ongoing
Product Name: Allura Xper FD10C; Model number: 722001; — Reason: Philips has identified that in a limited number of impacted systems the drip tray beneath the cooling unit was not installed under previous field corrections, or evidence of the implementation was not adequately documented. If it is not installed, there is a potential for coolant liquid to contact electrical components. This could lead to electrical short-circuits, which may trigger system fuses and result in system shutdown. — Status: Ongoing
Allura Xper FD10; Model Number: 722003; — Reason: Philips has identified that in a limited number of impacted systems the drip tray beneath the cooling unit was not installed under previous field corrections, or evidence of the implementation was not adequately documented. If it is not installed, there is a potential for coolant liquid to contact electrical components. This could lead to electrical short-circuits, which may trigger system fuses and result in system shutdown. — Status: Ongoing
ICU Medical Plum Duo Infusion Pump, List Numbers: 400020401 (US), 400021001 (Philippines) — Reason: Plum Solo and Duo Infusion pumps include a feature, that when selected, automatically flushes the downstream line after a piggyback therapy. The programmed flush volume is delivered from the primary line container at the piggyback therapy rate after the piggyback therapy is complete. In certain cases, as described below, the clinician may receive an Upper Hard Limit (UHL) or Lower Hard Limit (LHL) Violation message when programming a piggyback flush, which prevents the flush from being programmed. — Status: Ongoing
ICU Medical Plum Solo Precision IV Pump, List Numbers: 400010401 (US), 400011001 (Philippines) — Reason: Plum Solo and Duo Infusion pumps include a feature, that when selected, automatically flushes the downstream line after a piggyback therapy. The programmed flush volume is delivered from the primary line container at the piggyback therapy rate after the piggyback therapy is complete. In certain cases, as described below, the clinician may receive an Upper Hard Limit (UHL) or Lower Hard Limit (LHL) Violation message when programming a piggyback flush, which prevents the flush from being programmed. — Status: Ongoing
Allura Xper FD10/10; Model Number: 722011; — Reason: Philips has identified that in a limited number of impacted systems the drip tray beneath the cooling unit was not installed under previous field corrections, or evidence of the implementation was not adequately documented. If it is not installed, there is a potential for coolant liquid to contact electrical components. This could lead to electrical short-circuits, which may trigger system fuses and result in system shutdown. — Status: Ongoing
Allura Xper FD20/20; Model Number: 722038; — Reason: Philips has identified that in a limited number of impacted systems the drip tray beneath the cooling unit was not installed under previous field corrections, or evidence of the implementation was not adequately documented. If it is not installed, there is a potential for coolant liquid to contact electrical components. This could lead to electrical short-circuits, which may trigger system fuses and result in system shutdown. — Status: Ongoing
Brand Name: LEASEIR Product Name: LEASEIR MHR XCELL Model/Catalog Number: MHR 110-b Software Version: 1.5.0.0 Product Description: The Leaseir MHR Xcell is a surgical laser instrument for use in general and plastic surgery and dermatology, intended for hair removal and treatment of pseudo folliculitis barbae on all skin types (Fitzpatrick I-VI). The process implies the generation of intense light pulses at specific wavelengths. The specific nature of the energies and pulse durations cause the desired effect (in the hair follicles and oxyhemoglobin in the blood) heating them sufficiently and destroying them without unnecessary damage to surrounding tissue. This is achieved by controlled emission of laser radiation to the target tissue. The system consists of a main console and two interchangeable applicators that delivers pulsed light in the range of 800-820nm with a peak in the 810nm in different spot sizes. Two of the applicators emitting radiation at 810 nm wavelength for two areas 13.5¿15 mm¿ and 14.5¿25.5 mm¿. Two different operation modes are available: static mode and dynamic mode, which are differentiated basically by the frequency range defined for each mode (1-4 Hz for static and 10 Hz for dynamic). The principle of operation consists in the photons travel along the axis and reflected again back into the crystal, continuing the chain reaction, while photons travelling in different directions leave the crystal. In one of the two mirrors, a tiny hole allows a small amount of light to leak out and the resulting beam is focused with lenses and is emitted from the laser. The total energy emitted by the Leaseir MHR Xcell is produced by an array of diodes. The laser emission is activated by the hand piece trigger, deliver a continuous pulse pattern while the button is pressed. Component: NO — Reason: The console label for affected devices is missing the "DANGER" symbol. — Status: Ongoing
Allura Xper FD10/10; Model Number: 722005; — Reason: Philips has identified that in a limited number of impacted systems the drip tray beneath the cooling unit was not installed under previous field corrections, or evidence of the implementation was not adequately documented. If it is not installed, there is a potential for coolant liquid to contact electrical components. This could lead to electrical short-circuits, which may trigger system fuses and result in system shutdown. — Status: Ongoing
Allura Xper FD20; Model Number: 722012; — Reason: Philips has identified that in a limited number of impacted systems the drip tray beneath the cooling unit was not installed under previous field corrections, or evidence of the implementation was not adequately documented. If it is not installed, there is a potential for coolant liquid to contact electrical components. This could lead to electrical short-circuits, which may trigger system fuses and result in system shutdown. — Status: Ongoing
Asserachrom HPIA. Model/Catalog Number: 00615. The Asserachrom HPIA kit is intended for the qualitative detection in plasma or serum of the anti-heparin-platelet factor 4 (PF4) antibodies generated during the type II heparin-induced thrombocytopenia (HIT type II) by ELISA. — Reason: Potential for defect for Asserachrom HPIA lot 271288, which can affect every well in the impacted strip and produce negative results. — Status: Ongoing
Allura Xper FD20/10; Model Number: 722029; — Reason: Philips has identified that in a limited number of impacted systems the drip tray beneath the cooling unit was not installed under previous field corrections, or evidence of the implementation was not adequately documented. If it is not installed, there is a potential for coolant liquid to contact electrical components. This could lead to electrical short-circuits, which may trigger system fuses and result in system shutdown. — Status: Ongoing
ICU Medical Plum Duo Precision IV Pump, List Numbers: 400020403 (US), 400021003 (Philippines) — Reason: Plum Solo and Duo Infusion pumps include a feature, that when selected, automatically flushes the downstream line after a piggyback therapy. The programmed flush volume is delivered from the primary line container at the piggyback therapy rate after the piggyback therapy is complete. In certain cases, as described below, the clinician may receive an Upper Hard Limit (UHL) or Lower Hard Limit (LHL) Violation message when programming a piggyback flush, which prevents the flush from being programmed. — Status: Ongoing
Brand Name: Broselow Product Name: Broselow Domestic Complete ALS Organizer Model/Catalog Number: 7730ALS Software Version: Not Applicable Product Description: The Broselow Tape is a length- and weight-based reference tool specifically designed for pediatric emergency care. Component: No — Reason: Product contains potentially harmful dosing errors for Vecuronium, Flumazenil, and Ketamine. — Status: Ongoing
Allura Xper FD10; Model Number: 722010; — Reason: Philips has identified that in a limited number of impacted systems the drip tray beneath the cooling unit was not installed under previous field corrections, or evidence of the implementation was not adequately documented. If it is not installed, there is a potential for coolant liquid to contact electrical components. This could lead to electrical short-circuits, which may trigger system fuses and result in system shutdown. — Status: Ongoing
TS-10/TS-10H Tube Sorter, automatic sorting system for sorting barcoded sample tubes, Catalog Number BN168792, running software versions 00-17 — Reason: Under specific conditions, the lift's electromagnetic holding force may disengage unexpectedly, allowing unintended downward movement of the lift. — Status: Ongoing
Allura Xper FD20 Biplane; Model Number: 722008; — Reason: Philips has identified that in a limited number of impacted systems the drip tray beneath the cooling unit was not installed under previous field corrections, or evidence of the implementation was not adequately documented. If it is not installed, there is a potential for coolant liquid to contact electrical components. This could lead to electrical short-circuits, which may trigger system fuses and result in system shutdown. — Status: Ongoing
Brand Name: Broselow Product Name: BROSELOW" FILLED BROSELOW ORGANIZER Model/Catalog Number: 7730IALS Software Version: Not Applicable Product Description: The Broselow Tape is a length- and weight-based reference tool specifically designed for pediatric emergency care. Component: no — Reason: Product contains potentially harmful dosing errors for Vecuronium, Flumazenil, and Ketamine. — Status: Ongoing
Plum Duo Infusion System, List Number 40002-04-01 — Reason: ICU Medical received one lot of defective primary speakers from our supplier that may fail to produce an audible sound. If the primary speaker in your Plum Duo Infusion Pump fails, the pump may not produce audible alarms, alerts, or provide audible feedback for touchscreen inputs. — Status: Ongoing
Brand Name: Broselow Product Name: Broselow Pediatric Emergency Rainbow Tape Model/Catalog Number: 7700REA Software Version: Not Applicable Product Description: The Broselow Tape is a length- and weight-based reference tool specifically designed for pediatric emergency care. Component: No — Reason: Product contains potentially harmful dosing errors for Vecuronium, Flumazenil, and Ketamine. — Status: Ongoing
Brevera Breast Biopsy System Disposable 9 Gauge Needle. Biopsy Instrument. — Reason: Presence of particulates in affected devices that can be deposited into breast tissue during use. — Status: Ongoing
Allura Xper FD20 OR Table; Model Number: 722023; — Reason: Philips has identified that in a limited number of impacted systems the drip tray beneath the cooling unit was not installed under previous field corrections, or evidence of the implementation was not adequately documented. If it is not installed, there is a potential for coolant liquid to contact electrical components. This could lead to electrical short-circuits, which may trigger system fuses and result in system shutdown. — Status: Ongoing
Allura Xper FD20 Biplane; Model Number: 722013; — Reason: Philips has identified that in a limited number of impacted systems the drip tray beneath the cooling unit was not installed under previous field corrections, or evidence of the implementation was not adequately documented. If it is not installed, there is a potential for coolant liquid to contact electrical components. This could lead to electrical short-circuits, which may trigger system fuses and result in system shutdown. — Status: Ongoing
Product Name: Nasal Jejunal Feeding Tube REF: NJFT-10 — Reason: Nasal feeding tube packaged without the nasal transfer tube component. — Status: Ongoing
Allura Xper FD10; Model Number: 722026; — Reason: Philips has identified that in a limited number of impacted systems the drip tray beneath the cooling unit was not installed under previous field corrections, or evidence of the implementation was not adequately documented. If it is not installed, there is a potential for coolant liquid to contact electrical components. This could lead to electrical short-circuits, which may trigger system fuses and result in system shutdown. — Status: Ongoing
Allura Xper FD20; Model Number: 722006; — Reason: Philips has identified that in a limited number of impacted systems the drip tray beneath the cooling unit was not installed under previous field corrections, or evidence of the implementation was not adequately documented. If it is not installed, there is a potential for coolant liquid to contact electrical components. This could lead to electrical short-circuits, which may trigger system fuses and result in system shutdown. — Status: Ongoing
Convenience Kits 1. 25GA Convenience Kit - FNX VS0644.25-FNX 2. 25GA Convenience Kit - FXX VS0644.25-FXX 3.25GA Convenience Kit - XES VS0644.25-XES — Reason: There may be voids located in the seal of Tyvek pouches associated with identified catalog numbers and lots. A compromised sterile barrier has potential of bioburden contamination which could lead to infection. — Status: Ongoing
Medline medical procedure convenience kits labeled as: KIT ROBOTICS UROLOGY PROSTATE, REF DYKMBNDL116G — Reason: Medline kits containing Stryker's Strykeflow 2 Suction Irrigators due to a change in design in 2024, irrigation solution is able to travel to the handpiece and battery pack during use of the Strykeflow 2 Suction Irrigator. This design change has caused some devices to leak and/or emit vaporized saline (which can resemble smoke) during use. — Status: Ongoing
Medline medical procedure convenience kits labeled as: 1) LAVH PROCEDURE, REF CDS980754T; 2) GYN LAP HYSTERECTOMY CDS, REF CDS982662Q; 3) DAVINCI HYSTERECTOMY CDS, REF CDS985344F; 4) LAVH, REF DYNJQ9041R; 5) LAPAROSCOPIC HYSTERECTOMY, REF DYNJ900244I; 6) ROBOTIC LAVH, REF DYNJ901281I; 7) LAVH-LF, REF DYNJ901829T; 8) LEX LAP HYST, REF DYNJ902030J; 9) LITHOTOMY-SLINGS-LF, REF DYNJ905274D; 10) GYN LAPAROSCOPY, REF DYNJ905485J; 11) ROBOTIC HYSTERECTOMY, REF DYNJ906380C; 12) LAPAROSCOPIC HYSTERECTOMY, REF DYNJ910634; 13) LAVH GYN/ONC, REF DYNJ910927. — Reason: Medline kits containing Stryker's Strykeflow 2 Suction Irrigators due to a change in design in 2024, irrigation solution is able to travel to the handpiece and battery pack during use of the Strykeflow 2 Suction Irrigator. This design change has caused some devices to leak and/or emit vaporized saline (which can resemble smoke) during use. — Status: Ongoing
Vortex Surgical 1. 23GA Laser Probe Curved Cat No. VS0120.23 2. 25GA Laser Probe Curved Cat No. VS0120.25 3. 25GA Laser Probe Flex-Tip Cat No. VS0130.25 4. 25GA Laser Probe Illuminated Curved Cat No. VS0125.25B 5. 25GA Laser Probe MaxReach Cat No. VS0140.25 6. 25GA Laser Probe Straight Cat No. VS0110.25 — Reason: There may be voids located in the seal of Tyvek pouches associated with identified catalog numbers and lots. A compromised sterile barrier has potential of bioburden contamination which could lead to infection. — Status: Ongoing
Vortex Surgical TID Pharos Illuminated Depressor, VS0801B — Reason: XXX — Status: Ongoing
Vortex Surgical I2 Injection Kit, VS0500 — Reason: There may be voids located in the seal of Tyvek pouches associated with identified catalog numbers and lots. A compromised sterile barrier has potential of bioburden contamination which could lead to infection. — Status: Ongoing
Vortex Surgical 25GA Backflush, VS0270.25; 25GA Backflush Retractable, VS0275.27 — Reason: There may be voids located in the seal of Tyvek pouches associated with identified catalog numbers and lots. A compromised sterile barrier has potential of bioburden contamination which could lead to infection. — Status: Ongoing
Medline medical procedure convenience kits labeled as: 1) LAPAROSCOPY CDS-LF, REF CDS860235L; 2) GENERAL LAPAROSCOPIC, REF CDS930223M; 3) LAP CHOLE CDS, REF CDS983678K; 4) LAPAROSCOPY PELV CDS, REF CDS983679K; 5) LAP CHOLE CDS-LF, REF CDS983752M; 6) LAP CHOLE CDS-LF, REF CDS984016B; 7) LAP CHOLE KIT, REF CDS984020P; 8) LAP CHOLE-LF, REF CDS984175J; 9) LAP COLON CDS, REF CDS984849N; 10) GENERAL LAPAROSCOPY CDS, REF CDS985328M; 11) LAP CHOLE, REF DYNJQ9044O; 12) GENERAL LAPAROSCOPY V, REF DYNJS2032F; 13) LAP CHOLE PACK, REF DYNJ26209R; 14) LAP CHOLE PACK, REF DYNJ26209S; 15) GENERAL LAPAROSCOPY PACK, REF DYNJ37459D; 16) DR. BROWN LAP CHOLE PLUS SETUP, REF DYNJ42578G; 17) LAPAROSCOPY GENERAL PACK, REF DYNJ45083G; 18) LAP CHOLE PACK, REF DYNJ51785D; 19) LAPAROSCOPY PACK, REF DYNJ61652A; 20) ENDOSCOPY, REF DYNJ62133A; 21) LAP CHOLE PACK, REF DYNJ66285A; 22) LAPAROSCOPY PACK, REF DYNJ66289B; 23) LAPAROSCOPIC CHOLECYSTECTO, REF DYNJ67296D; 24) LAPAROSCOPY PACK, REF DYNJ68187A; 25) LAP OB PACK, REF DYNJ68741A; 26) LAP CHOLE PACK-LF, REF DYNJ81408A; 27) LAP CHOLE PACK-LF, REF DYNJ81408B; 28) LAP CHOLE PACK, REF DYNJ85318; 29) GENERAL LAPAROSCOPY PACK, REF DYNJ89677; 30) LEX GENERAL LAPAROSCOPY, REF DYNJ900969J; 31) LAP CHOLE, REF DYNJ901126G; 32) BARIATRIC KIT, REF DYNJ901145I; 33) GENERAL LAPAROSCOPY SOMC-LF, REF DYNJ901164M; 34) LAP GASTRIC SLEEVE, REF DYNJ901504L; 35) GENERAL LAP GASTRIC, REF DYNJ901827X; 36) GENERAL LAPAROSCOPY, REF DYNJ901847N; 37) LOU LAP SIGMOID COLON, REF DYNJ901848L; 38) LAP CHOLE, REF DYNJ901870J; 39) LEX BARIATRIC, REF DYNJ902033L; 40) BARIATRIC, REF DYNJ902515K; 41) LAP CHOLE CDS, REF DYNJ902565K; 42) LAP CHOLE, REF DYNJ902995I; 43) LAP CHOLE, REF DYNJ903163L; 44) LAP APPY, REF DYNJ903164L; 45) GENERAL SURGERY LAPAROSCOPY, REF DYNJ903733C; 46) LAP CHOLE, REF DYNJ904693D; 47) BARIATRIC, REF DYNJ904891N; 48) LAPAROSCOPY, REF DYNJ905071F; 49) KIT GENERAL LAPAROSCOPY MHS, REF DYNJ905390F; 50) KIT GENERAL LAPAROSCOPY MHS, REF DYNJ905390G; 51) KIT GENERAL LAPAROSCOPY WEILER, REF DYNJ905407D; 52) KIT GENERAL LAP WAKEFIELD, REF DYNJ905413A; 53) KIT GENERAL LAP WAKEFIELD, REF DYNJ905413B; 54) LAP BARIATRIC, REF DYNJ905733K; 55) KIT LAPAROSCOPIC GASTRIC B, REF DYNJ905856A; 56) LAP CHOLE, REF DYNJ906277D; 57) LAP CHOLE RFD, REF DYNJ906302D; 58) KIT LAP COLON RFD, REF DYNJ906315D; 59) GASTRIC SLEEVE, REF DYNJ906355D; 60) PROSTATECTOMY LAP ROBOTIC, REF DYNJ906805C; 61) LAP ROBOTIC SURG ONCOLOGY, REF DYNJ906824C; 62) GEN BARIATRIC, REF DYNJ907639D; 63) LAP CHOLE, REF DYNJ908415B; 64) LAP CHOLE, REF DYNJ908415C; 65) LAPAROSCOPIC, REF DYNJ908569B; 66) ROBOTIC GASTRIC LAP SLEEVE-LF, REF DYNJ909119G; 67) LAPAROSCOPIC GASTRIC ADD ON, REF DYNJ909628A; 68) BARIATRIC CENTRASTATE, REF DYNJ909817A; 69) LAP GENERAL THEDA, REF DYNJ910050; 70) LAPAROSCOPIC CHOLE PACK, REF DYNJ910139A; 71) ROBOTIC THORACIC, REF DYNJ910386; 72) BARIATRIC, REF DYNJ911017. — Reason: Medline kits containing Stryker's Strykeflow 2 Suction Irrigators due to a change in design in 2024, irrigation solution is able to travel to the handpiece and battery pack during use of the Strykeflow 2 Suction Irrigator. This design change has caused some devices to leak and/or emit vaporized saline (which can resemble smoke) during use. — Status: Ongoing
Oertli 1. 23G Laser Probe OS4 Flex-Tip VK401113 2. 23G Laser Probe OS4 Illuminated Flex-Tip VK401213 3. 23G Laser Probe OS4 Intuitive Exendable VK401323 4. 25G Laser Probe OS4 Flex-Tip VK401115 5. 25G Laser Probe OS4 Illuminated Flex-Tip VK401215 6. 25G Laser Probe OS4 Intuitive Exendable VK401325 7. 27G Laser Probe OS4 Intuitive Exendable VK401327 — Reason: There may be voids located in the seal of Tyvek pouches associated with identified catalog numbers and lots. A compromised sterile barrier has potential of bioburden contamination which could lead to infection. — Status: Ongoing
Vortex Surgical 25GA I.D.D. Internal Delivery Device, VS0250.25 — Reason: There may be voids located in the seal of Tyvek pouches associated with identified catalog numbers and lots. A compromised sterile barrier has potential of bioburden contamination which could lead to infection. — Status: Ongoing
Tecfen Retractable Membrane Polisher, QTPR1267-23 — Reason: There may be voids located in the seal of Tyvek pouches associated with identified catalog numbers and lots. A compromised sterile barrier has potential of bioburden contamination which could lead to infection. — Status: Ongoing
25GA Subretinal Injection Cannula VS0220.25 — Reason: There may be voids located in the seal of Tyvek pouches associated with identified catalog numbers and lots. A compromised sterile barrier has potential of bioburden contamination which could lead to infection. — Status: Ongoing
Vortex Disposable Forceps and Cannula 1. 23GA ACTU8 Forceps Adaptive VS0740.23 2. 25GA ACTU8 Forceps Adaptive VS0740.25 3. 25GA ACTU8 Forceps ILM VS0744.25 4. 25GA ACTU8 Forceps ILM -Myopic VS0744.25-35 5. 25GA ACTU8 Forceps Pro-Grip VS0713.25 6. 25GA ACTU8 Talon Forceps ILM VS0752.25 7. 25GA ACTU8 Talon Forceps Pro-Grip VS0751.25 8. 27GA ACTU8 Forceps ILM VS0744.27 9. 23GA Soft Tip Cannula VS0200.23 10. 23GA Soft Tip Cannula - 0.5mm VS0205.23 11. 25GA Soft Tip Cannula VS0200.25 12. 25GA Soft Tip Cannula - 0.5mm VS0205.25 13. 25GA Soft Tip Cannula - 0.5mm - Bulk VS0205.25B 14. 25GA Soft Tip Cannula-Bulk VS0200.25B 15. 27GA Soft Tip Cannula VS0200.27 — Reason: There may be voids located in the seal of Tyvek pouches associated with identified catalog numbers and lots. A compromised sterile barrier has potential of bioburden contamination which could lead to infection. — Status: Ongoing
Medline medical procedure convenience kits labeled as: 1) THORACIC ROBOTICS, REF DYNJ908777B; 2) CARDIAC ROBOTIC WHC KIT-LF, REF DYNJ911359 — Reason: Medline kits containing Stryker's Strykeflow 2 Suction Irrigators due to a change in design in 2024, irrigation solution is able to travel to the handpiece and battery pack during use of the Strykeflow 2 Suction Irrigator. This design change has caused some devices to leak and/or emit vaporized saline (which can resemble smoke) during use. — Status: Ongoing