pharmadog
News
when
  • Latest
  • Archive
by source
  • All Sources
  • Sources Page
Jobs
department
  • Clinical
  • Regulatory
  • Medical Affairs
  • Commercial
  • R&D / Discovery
  • Biostatistics / Data
  • Manufacturing / CMC
  • Market Access
therapeutic area
  • Oncology
  • Immunology
  • Neuroscience
  • Cardiovascular
  • Metabolic
  • Rare Disease
  • Infectious Disease
location & type
  • Remote Only
  • US Only
  • California
  • Massachusetts
  • Internships
  • Phase 3 Roles
  • All Jobs →
Sign InSubscribe
pharmadog

fetch the data · sniff the signal

Discover
  • Jobs
  • News
Hubs
  • Topics
  • Patent cliff
  • Publications
Tools
  • Compare
  • Search
  • Bookmarks
Trust
  • About
  • Sources
  • Contact
Legal
  • Privacy
  • Terms
  • Pricing

© 2026 pharmadog.xyz

made by humans and a good dog

  • home
  • jobs
  • news
  • search

calendar

181 catalysts · 123 device recall · 20 device 510k · 17 approval · 12 recall · 9 device pma

★ save view↓export CSV
next 91 dayslessmore
MonWedFri
2026-08-10: 0 catalysts2026-08-11: 0 catalysts2026-08-12: 0 catalysts2026-08-13: 0 catalysts2026-08-14: 0 catalysts2026-08-15: 0 catalysts2026-08-16: 0 catalysts2026-08-17: 1 catalyst2026-08-18: 2 catalysts2026-08-19: 3 catalysts2026-08-20: 0 catalysts2026-08-21: 0 catalysts2026-08-22: 0 catalysts2026-08-23: 0 catalysts2026-08-24: 0 catalysts2026-08-25: 0 catalysts2026-08-26: 1 catalyst2026-08-27: 1 catalyst2026-08-28: 0 catalysts2026-08-29: 0 catalysts2026-08-30: 0 catalysts2026-08-31: 0 catalysts2026-09-01: 1 catalyst2026-09-02: 0 catalysts2026-09-03: 1 catalyst2026-09-04: 0 catalysts2026-09-05: 0 catalysts2026-09-06: 0 catalysts2026-09-07: 0 catalysts2026-09-08: 0 catalysts2026-09-09: 0 catalysts2026-09-10: 0 catalysts2026-09-11: 0 catalysts2026-09-12: 0 catalysts2026-09-13: 0 catalysts2026-09-14: 0 catalysts2026-09-15: 0 catalysts2026-09-16: 0 catalysts2026-09-17: 0 catalysts2026-09-18: 0 catalysts2026-09-19: 0 catalysts2026-09-20: 0 catalysts2026-09-21: 0 catalysts2026-09-22: 0 catalysts2026-09-23: 2 catalysts2026-09-24: 0 catalysts2026-09-25: 0 catalysts2026-09-26: 0 catalysts2026-09-27: 0 catalysts2026-09-28: 0 catalysts2026-09-29: 0 catalysts2026-09-30: 0 catalysts2026-10-01: 0 catalysts2026-10-02: 0 catalysts2026-10-03: 0 catalysts2026-10-04: 0 catalysts2026-10-05: 0 catalysts2026-10-06: 0 catalysts2026-10-07: 0 catalysts2026-10-08: 2 catalysts2026-10-09: 0 catalysts2026-10-10: 0 catalysts2026-10-11: 0 catalysts2026-10-12: 0 catalysts2026-10-13: 1 catalyst2026-10-14: 1 catalyst2026-10-15: 0 catalysts2026-10-16: 0 catalysts2026-10-17: 0 catalysts2026-10-18: 0 catalysts2026-10-19: 1 catalyst2026-10-20: 2 catalysts2026-10-21: 2 catalysts2026-10-22: 2 catalysts2026-10-23: 1 catalyst2026-10-24: 0 catalysts2026-10-25: 0 catalysts2026-10-26: 1 catalyst2026-10-27: 8 catalysts2026-10-28: 12 catalysts2026-10-29: 21 catalysts2026-10-30: 4 catalysts2026-10-31: 0 catalysts2026-11-01: 0 catalysts2026-11-02: 9 catalysts2026-11-03: 18 catalysts2026-11-04: 22 catalysts2026-11-05: 37 catalysts2026-11-06: 2 catalysts2026-11-07: 0 catalysts2026-11-08: 0 catalysts
view
agendamonth
sort
soonestlatesttypesponsoralpha
from 2025-10-29×to 2025-10-29×clear all
type
  • device recall123
  • device 510k20
  • approval17
  • recall12
  • device pma9
therapy area

no tagged catalysts yet

Week of Oct 27, 2025

50
›Oct 29, 2025device pma291d agoBoston Scientific Corporation — SYNERGYTM Everolimus-Eluting Platinum Chromium Coronary Stent System (PMA supplement)BOSTON SCIENTIFIC CORP

Supplement type: 30-Day Notice. Product code: NIQ. Advisory committee: CV. Decision: OK30

full page →fda device pma ↗
›Oct 29, 2025device pma291d agoHighridge Medical, LLC — LDR Spine Mobi-C® Cervical Disc Prosthesis (PMA supplement)

Supplement type: Normal 180 Day Track No User Fee. Product code: MJO. Advisory committee: OR. Decision: APPR

full page →fda device pma ↗
›Oct 29, 2025device pma291d agoBiotronik, Inc. — Pamira S 60 428768 Pamira S 65 428769 Pamira S 75 428770 Pamira SD 60/16 428771 Pamira SD 65/16 428772 Pamira SD 65/18 4 (PMA supplement)

Supplement type: 30-Day Notice. Product code: LWS. Advisory committee: CV. Decision: OK30

full page →fda device pma ↗
›Oct 29, 2025device pma291d agoZoll Circulation, Inc. — TherOx Downstream System (PMA supplement)

Supplement type: 30-Day Notice. Product code: MWG. Advisory committee: CV. Decision: OK30

full page →fda device pma ↗
›Oct 29, 2025device pma291d agoOrbusNeich Medical (Shenzhen) Co., Ltd. — Scoreflex NC Scoring PTCA Catheter (PMA supplement)

Supplement type: 30-Day Notice. Product code: NWX. Advisory committee: CV. Decision: OK30

full page →fda device pma ↗
›Oct 29, 2025device pma291d agoMedtronic, Inc. — OmniaSecure™ MRI SureScan™ Lead Model 3930M (PMA supplement)Medtronic plc

Supplement type: 30-Day Notice. Product code: NVY. Advisory committee: CV. Decision: OK30

full page →fda device pma ↗
›Oct 29, 2025device pma291d agoVascutek, Ltd. — Thoraflex™ Hybrid (PMA supplement)

Supplement type: 30-Day Notice. Product code: QSK. Advisory committee: CV. Decision: OK30

full page →fda device pma ↗
›Oct 29, 2025device pma291d agoHighridge Medical, LLC — LDR Spine Mobi-C® Cervical Disc Prosthesis (PMA supplement)

Supplement type: Normal 180 Day Track No User Fee. Product code: MJO. Advisory committee: OR. Decision: APPR

full page →fda device pma ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

Blood Administration Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. Y-TYPE BLOOD SET W/ 170 ?M FILTER 120 IN; Catalog Number: 490355. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

IV Administration Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. IV ADMIN SET W/15 DROPS/ML 126 IN; Catalog Number: 490283. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

Blood Administration Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. Y-TYPE BLOOD SET 124 IN.; Catalog Number: 490196. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

SafeDAY set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. IV ADM SET 15 DR W/2 SAFEDAY & STOPCOCK; Catalog Number: 352646. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

IV Administration Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. IV ADMIN 15D, 2 B/C VLV, 3 CARESITE LADS; Catalog Number: 490653. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

Anesthesia IV Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. IV ADMIN SET W/15 DROPS/ML, 132 IN; Catalog Number: 490469. 2. IV ADMIN SET, 60D 2 CARESITE VLV, 132 IN; Catalog Number: 490470. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

Infusomat utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog numbers: 1. UNIV.15DROP PUMP SET W/3 SAFELINE LL; 15 drops/mL, priming volume: 22mL, length: 119in, SafeLine; Catalog Number: 362032. 2. UNIV. 15 DR PUMP SET, 1.2 FIL, 2 CRSITE; UNIV. 15 DR PUMP SET, 1.2 FIL, 2 CRSITE; Catalog Number: 362033. 3. 60DROP METRISET PUMP SET, 3 SAFELINE; Priming volume: 19mL, length: 120in, SafeLine; Catalog Number: 362034. 4. Y TYPE BLOOD PUMP SET, SAFELINE INJ; Priming volume: 39mL, length: 120in, SafeLine¿; Catalog Number: 362043. 5. UNIV. 15 DROP PUMP SET W/ 0.2 FILTER; 15 drops/mL, priming volume: 26mL, length: 124in, SafeLine; Catalog Number: 362050. 6. SPACE PUMP SET 15 DROP W/2 SAFEDAY; SPACE PUMP SET 15 DROP W/2 SAFEDAY; Catalog Number: 362420. 7. UNIV. 15 DROP PUMP SET W/ 3 ULTRASITE LL; 15 drops/mL, priming volume: 21mL, length: 120in, ULTRASITE; Catalog Number: 362431. 8. SPACE PUMP IV SET, 120 IN.; 15 drops/mL, priming volume: 21mL, length: 118in, ULTRASITE; Catalog Number: 362432. 9. 60 DROP METRISET PUMP SET,3 SFLINE ASV; Priming volume: 21mL, length: 121in, SafeLine; Catalog Number: 363010. 10. Y-TYPE BLOOD PUMP SET, SAFELINE, ASV; Priming volume: 40mL, length: 123in, SafeLine; Catalog Number: 363019. 11. UNIV. 15 DROP PUMP SET W/3 SAFELINE, ASV; 15 drops/mL, priming volume: 22mL, length: 119in, SafeLine; Catalog Number: 363030. 12. UNIV. 15 DROP PUMP SET, 3 ULTRASITE, ASV; 15 drops/mL, priming volume: 22mL, length: 123in, ULTRASITE; Catalog Number: 363230. 13. Y-TYPE BLOOD PUMP SET, CARESITE, ASV; Priming volume: 41mL, length: 120in, CARESITE; Catalog Number: 363419. 14. SPACE PUMP IV SET, 2 CARESITES, ASV; 15 drops/mL, priming volume: 24mL, length: 120in, CARESITE; Catalog Number: 363420. 15. UNIV. 15 DROP PUMP SET, 2 CARESITE, ASV; 15 drops/mL, priming volume: 22mL, length: 120in, CARESITE; Catalog Number: 363421. 16. 60DROP METRISET PUMP, 3 CARESITES, ASV; Priming volume: 21mL, length: 130in, CARESITE; Catalog Number: 363422. 17. UNIV. 60 DROP PUMP SET, 2 CARESITES, ASV; 60 drops/mL, priming volume: 21mL, length: 118in, CARESITE; Catalog Number: 363423. 18. UNIV. 15 DR PUMP SET, 1.2FIL, 2CRSTE ASV; UNIV. 15 DR PUMP SET, 1.2FIL, 2CRSTE ASV; Catalog Number: 363424. 19. UNIV. 15 DROP PUMP SET, 3 CARESITE, ASV; 15 drops/mL, priming volume: 23mL, length: 123in, CARESITE; Catalog Number: 363430. 20. UNIV. 15 DROP PUMP SET, 3 CARESITE, ASV; UNIV. 15 DROP PUMP SET, 3 CARESITE, ASV; Catalog Number: 363433. 21. SPACE PUMP IV SET 15D, 110 IN.; "SPACE PUMP IV SET 15D, 110 IN. CLOSE"; Catalog Number: 480254. 22. SPACE PUMP IV SET, 127 IN.; SPACE PUMP IV SET, 127 IN.; Catalog Number: 480255. 23. SPACE PUMP SET 15D, CARESITE LAD 122 IN. ; 15 drops/mL, priming volume: 23mL, length: 122in, CARESITE; Catalog Number: 480256. 24. 15 DROP PUMP SET 1 SAFEDAY 0.2 FILTER; 15 DROP PUMP SET 1 SAFEDAY 0.2 FILTER; Catalog Number: 480258. 25. SPACE PUMP IV SET 15D, 90 IN.; SPACE PUMP IV SET 15D, 90 IN.; Catalog Number: 480263. 26. UNIV. 15 DROP PUMP SET W 3 CARESITE L.L.; 15 drops/mL, priming volume: 22mL, length: 120in, CARESITE; Catalog Number: 490100. 27. 60 DROP METRISET PUMP SET, 3 CARESITES; Priming volume: 19mL, length: 120in, CARESITE; Catalog Number: 490101. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

Extension Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. EXT/2INJ/FLBL/FML LRLK/CV 34; Catalog Number: V5405. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

IV Administration Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. PB1500 15 DROP IV SET W/2 STOPCOCKS; Catalog Number: 490025. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

IV Administration Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. AESTHESIA IV SET, 127 in.; Catalog Number: 490551. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

IV Administration Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. Catalog Number: 490549; Primary UDI-DI: 04046955270323; Unit of Dose UDI-DI: 04046955270316; Expiration Date: Earliest Exp of Comp or 36mths. 2. Catalog Number: 490565; Primary UDI-DI: 04046955275601; Unit of Dose UDI-DI: 04046955275595; Expiration Date: Earliest Exp of Comp or 36mths. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

IV Administration Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. IV SET 3 CARESITE ULTRA ZERO 2/SWAB SAFE; IV Set With 3 CARESITE Injection Sites, ULTRAPORT Zer0 High-Flow, 4-Way Stopcock, and Dual Port SAFEPORT; Catalog Number: 457515. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

IV Administration Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. IV ADMINISTRATION SET, 138 IN.; Catalog Number: 490491. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

Extension Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. EXTENSION SET W/ B/C VALVE 53 in.; Catalog Number: 490358. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

IV Administration Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. IV ADMIN SET W/ B/C VALVE,103 IN.; Catalog Number: 470179. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

Extension Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog numbers: 1. ANESTHESIA SET W/ SAFEPORT MANIFOLD; Catalog Number: 456521. 2. ANES SET W/TRIPLE LL SAFEPORT MANIFOLD; Catalog Number: 456522. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

IV Administration Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. NF1505, IV ADMIN SET W/2 H.F. STOPCOCKS; Catalog Number: 490088. 2. IV ADMIN SET W/2 SAFELINE & HF STOPCOCK; Catalog Number: 490107. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

Outlook set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. OUTLOOK IV SET 15DROP W/2 CARESITE; Catalog Number: 354212. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

IV Administration Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. IV ADM 15D 2 CARESITE, SAFEPORT MANIFLD; Catalog Number: 354208. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

IV Administration Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. IV ADMIN SET 15DR HF 4-WAY STPCK 135 IN.; Catalog Number: 490193. 2. IV AD SET, 2 CARESITE, SAFEPORT, 134 IN.; Catalog Number: 490326. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoMedicrea International device recall (Cls II)Jin Medical International Ltd.

Medicrea, IB3D PL Instruments Set, Rx Only REF: SPS03174 — Reason: Due to complaints, orthopedic rotation tool handle may untread from the shaft resulting in the inability to rotate implant. — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

IV Administration Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. IV ADM 15 DROP W/3 CARESITE N/C DUAL; Catalog Number: 354211. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoPhilips North America Llc device recall (Cls II)

CT 5300; Software Version Number: 4.5, 5.0, 5.1; — Reason: If the screws of tube heat exchanger on the rotating scanner are not tightened well after replacing. This component may become detached and make contact with other components located within the Incisive CT systems during rotation. Other components could be damaged due to the contact with the tube heat exchanger. — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

IV Administration Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. IV ADMIN SET W/60 DR/ML, CARESITE,147 IN.; Catalog Number: 490367. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

Blood Administration Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. Y-TYPE BLOOD SET, 3 CARSITE LADS, 146 IN; Catalog Number: 490530. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

Vista set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. VISTA BASIC PUMP IV SET W/ 15 DROP/ML; Catalog Number: US9923F. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

Extension Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. EXT SET W/ 6 B/C VALVES, 17 IN; Catalog Number: 490238. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

IV Administration Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. IV ADMIN SET 15 DR W/2 SAFEDAY; Catalog Number: 352636. 2. IV ADMIN SET 15 DR W/2 SAFEDAY 84 IN.; Catalog Number: 352639. 3. IV ADMIN SET 15 DROP W/3 SAFEDAY; Catalog Number: 352640. 4. IV ADMIN 15D W/2 SAFEDAY & 0.2 FILTER; Catalog Number: 352643. 5. IV ADMIN SET, 105 IN.; Catalog Number: 477003. 6. IV ADMIN SET 15D, 4 CARESTIE LAD, 145 IN; Catalog Number: 477006. 7. IV ADMIN SET, 121 IN.; Catalog Number: 477008. 8. IV ADMIN SET 15D, CARESTIE LAD, 90 IN; Catalog Number: 477012. 9. IV ADMIN SET, 2 CARESTIE LAD, 15D, 117IN; Catalog Number: 477019. 10. IV ADMIN SET, 15D, 5CARESITE LAD, 136 IN; Catalog Number: 477021. 11. IV ADMIN SET 114 IN.; Catalog Number: 477022. 12. IV ADMIN SET 5 CARESITE LADS, 126 IN.; Catalog Number: 477023. 13. IV SET 15DR 3 SAFEDAY, 106 IN.; Catalog Number: 477053. 14. IV ADMIN SET, 15DR, CARESITE LAD, 121 IN; Catalog Number: 490513. 15. IV ADMIN SET, 15D, 120 IN.; Catalog Number: 490521. 16. IV ADMIN SET 15D 2 CARESITE LADS, 112IN.; Catalog Number: 490527. 17. IV ADMIN SET 15 DRP CARESITE SAFEPORT; Catalog Number: 490529. 18. IV ADMIN SET, 15D, 139 IN.; Catalog Number: 490535. 19. IV ADMIN SET 15D, CARESITE LAD, 122IN.; Catalog Number: 490543. 20. IV ADMIN SET 15D 3 CARESITE LADS, 150IN.; Catalog Number: 490546. 21. IV ADMIN SET, 125 IN.; Catalog Number: 490547. 22. IV ADMIN SET 15D, 5 CARESITE INJ, 150in.; Catalog Number: 490552. 23. IV ADMIN SET, 120IN.; Catalog Number: 490553. 24. IV ADMIN SETW/ B/C VLV 3 CARESITE 134IN.; Catalog Number: 490554. 25. IV ADMIN SET 15DR w/3 B/C VLV, 124 IN.; Catalog Number: 490555. 26. IV ADMIN SET 15D w/B/C VLV, 139 IN.; Catalog Number: 490558. 27. IV ADMINISTRATION SET, 117 IN.; Catalog Number: 490559. 28. IV ADMINISTRATION SET, 108 IN.; Catalog Number: 490560. 29. IV ADMINISTRATION SET, 134 IN.; Catalog Number: 490561. 30. IV ADMIN SET 15D w/B/C VLV, 140 IN.; Catalog Number: 490562. 31. IV ADMIN SET, 111 IN.; Catalog Number: 490563. 32. IV ADMIN SET 15D 2 CARESITE LADS, 122 IN; Catalog Number: 490569. 33. IV ADMIN SET 15D STOPCOCK, DUAL MANIFOLD; Catalog Number: 490573. 34. IV ADMIN SET 15D w/B/C VLV, 110 IN.; Catalog Number: 490574. 35. IV ADMIN 15D 5 CARESITE LADS STPCK 120in; Catalog Number: 490575. 36. IV ADMIN SET 15D 5 CARESITE LADS, 140 IN; Catalog Number: 490578. 37. IV ADMIN SET W/15D, 4 CARESITE LADS; Catalog Number: 490581. 38. IV ADMIN 15D CARESITE LADS, STPCK 134 IN; Catalog Number: 490582. 39. IV ADMIN SET, 15D, 108 IN.; Catalog Number: 490583. 40. IV ADMIN SET, 10 DROP, 130 IN.; Catalog Number: 490588. 41. IV ADMIN SET, 132 IN.; Catalog Number: 490589. 42. IV ADMIN SET, 15DR, 105 IN.; Catalog Number: 490600. 43. IV ADMIN SET,3 CARESITE,3 HF SPCK, 129IN; Catalog Number: 490607. 44. IV SET 15DR 3CARESITE 2STOPCOCK, 126IN; Catalog Number: 490608. 45. IV ADMIN SET 15D 2 CARESITE LADS, 138 IN; Catalog Number: 490615. 46. IV SET 15DR 2SAFEDAY 2SAFEPORT, 99 IN.; Catalog Number: 490618. 47. IV SET 60DR 2SAFEDAY 2SAFEPORT, 99 IN.; Catalog Number: 490619. 48. IV ADMIN SET 15 DRPS 4W STOPCOCK W/ C&S; Catalog Number: 490644. 49. IV ADMIN SET 15 DRPS ULTRAP. ZERO 90.6IN; Catalog Number: 490657. 50. IV ADMIN SET 15 DRPS STOPCOCK MALE 117IN; Catalog Number: 490658. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

IV Administration Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog numbers: 1. IV ADMIN SET, 10 DROPS/ML, 144 IN; Catalog Number: 490385. 2. IV ADMIN SET, 3 CARESITES, 120 IN.; Catalog Number: 490401. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

IV Administration Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. IV ADMIN SET W/15 DROPS/ML, 133 IN.; Catalog Number: 490245. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

IV Administration Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. IV ADMIN SET, QUAD MANIFOLD,120 IN.; Catalog Number: 490340. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

Extension Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. EXT SET W/ B/C VLV, ULTRAPORT, 57 IN.; Catalog Number: 490202. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

IV Administration Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. IV ADMIN SET, 15DR, CARESITE LAD, 116 IN; Catalog Number: 490522. 2. IV ADMIN SET 115, IN. W. 9 IN EXT SET; Catalog Number: 490568. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

IV Administration Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. IV ADMIN SET 60 DROP/ML, 105 IN.; Catalog Number: 490242. 2. IV ADMN SET W/15 DROP,2 CARESITE,142 IN.; Catalog Number: 490311. 3. IV ADMIN SET W/15 DROPS/ML 115 in.; Catalog Number: 490353. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

ADDitIV utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog numbers: 1. Primary Gravity IV Set, 2 Non-Needle-Free Injection Sites; Catalog Number: V1443. 2. ADDITIVE SET W/ 3 INJ SITES -DR*; Catalog Number: V1447. 3. ADD PEDIATRIC 3 INJ LUER LOCK; Catalog Number: V1448. 4. ADULT ADD 2 INJ CKV LUER LOCK; Catalog Number: V1484. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

IV Administration Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. IV ADMIN SET, 110 IN.; Catalog Number: 490566. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

Burette Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. BURETTE SET, 4 CARESITE LADS, STPCK 125"; Catalog Number: 490252. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

IV Administration Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. IV ADMIN SET 15D, 2 CARESITES, 153 IN.; Catalog Number: 490542. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

IV Administration Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. NF1500UP, IV ADMINISTRATION SET; Catalog Number: 490070. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

Anesthesia IV Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. IV ADMIN SET, 15 DROPS/ML 125 IN; Catalog Number: 490452. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

IV Administration Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. IV SET W/2 CARESITE & 1 ULTRAPORT ZERO; ULTRAPORT Zer0 IV Set with CARESITE; Catalog Number: 457506. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗
›Oct 29, 2025device recall291d agoB Braun Medical Inc device recall (Cls II)B. Braun Medical Inc

Extension Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. ANES SET W/DUAL FEM.LL SAFEPORT MANIFOLD; Catalog Number: 456520. — Reason: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). — Status: Ongoing

full page →fda device recalls ↗